The Landing Gear Mechanism Trainer includes all assemblies and components of the standard hydraulically operated landing gear system. Two types of trainers are available; comprises of three wheels comprising two main landing gears and one nose gear, and has one wheel. The Landing Gear Mechanism Trainer is very valuable equipment for the hands-on training for aircraft maintenance training schools. Trainer is a very effective hands on training system for landing gear system. Both models depict the landing gear mechanism as found in actual aircraft. The model is mounted on a move able stand to facilitate easy positioning of the trainer for a clear view from all directions. It is essential to ensure that trainees not only understand the theory but they are also well prepared to maintain the landing gear system in the best possible manner, and in compliance with the prevailing safety standards.
Features:
1-Tire Assembly
Filter
Fluid Reservoir
Actuating Cylinder
Wheel
Tires
2-Hydraulic Brake Components
Fluid Reservoir
Brake Assembly
Master Brake Cylinder
3- Hydraulically Operated Landing Gear
Electrically Driven Hydraulic Pump
Relief Valves
Emergency Hand Pump.
Air craft Radio Altimeter System Trainer is a fully functional radio altimeter system comprising of actual airborne avionics equipment. They are also abbreviated as Rad. Alt. in avionics terminology. The terms Radio Altimeter and Radar Altimeter are used interchangeably and essentially mean the same.
The Radio Altimeter System Trainer is comprised of the following items:
Bench-mounted mobile workstation
Radio Altimeter Tx and Rx Antennas
Radio Altimeter Transmitter/Receiver
Radio Height Indicator
Test Set Antenna Couplers, qty. 2
Test Set
Power Supply
All necessary wiring harnesses
Features:
Solid-stat eRadio Altimeter Receiver/ Transmitter Unit
Digital altitude processor for long, drift-free operation
Rugged,die-cast construction of the Receiver/Transmitter Unit
Radio Altitude Indicator
Operates on28 volt DC power
Has serial digital output for use by other avionics equipment like FMS and Autopilots
Self test to enable rapid verification of proper system function
Standard radio altimeter antenna used in general aviation aircraft
Adjustable Decision Height function provided to alert pilot via lamp and aural tone that the aircraft has descended to a selected altitude
Aircraft in the air simulation
Fixed, linear variable, and flight profile altitude simulation
Aircraft on Ground simulation
Para metrictesting functions.
Sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line. The set-up consists of different pressure measurement devices fitted in a pipe line, in which an Orifice is fitted to create the pressure difference.
Learning Objects/Experimentation:
To measure the pressure and pressure difference by pressure gauge, single column manometer, U Tube manometer & Inclined tube manometer.v
To demonstrate the working of different pressure measuring devices.
Requirment For Operation:
Water Supply (Initial fill)
Floor Drain required.
Electricity Supply: Single phase, 220 VAC, 50 Hz, 5-15 amp.
Combined socket with earth connection.
Mercury (Hg) for manometer (750 gm).
Floor Area Required: 1.5 m x 0.75 m.
Castors are fitted to the Workstation which enable it to be easily moved between locations.
The workstation can be used as a demonstration platform at the front of the classroom, but also doubles up as a storage unit for the experiment trays and Base Units.
Features And Benefits:
Ability to store both the experiment trays and base units
The workstation can be configured to store:- Up to 12 base units and a maximum of 18 trays (2 base units occupy the space of 1 tray)
18 trays if storing no base units
12 base units and 12 trays
Castors allow the workstation and its contents to be easily moved between locations
Flat top can be used as a demonstration platform.
The hydraulic system applies either a tensile or compressive loading to specimens. Extension of the specimen is monitored using an extensometer for work on stress/strain curves and the Modulus of Elasticity. This Universal Material Tester is a bench top unit for training purposes. The applied force to the specimens is created using a digital pressure sensor and shown on the Digital Interface supplied. An elongation sensor is also supplied for use in bending, compressive and shear testing. Simple operation and robust construction make the unit suitable for student experiments. The round threaded tensile specimens are installed between upper and lower fixings using the mating threads in each fixing. A wide variety of options are also available. Data Acquisition Software is supplied as standard to enable the test parameters to be captured, displayed, reviewed and printed.
Experimental Capabilities:
Tensile Strength Percentage Elongation
Tensile and Compressive testing Recording of stress-strain diagrams Modulus of Elasticity testing.
Rectangular mosquito net, polyethylene 120-150 DENIER, treated with WHO PQ qualified insecticide, colour white/blue/green, alternative dimensions.
....Intended use:
Various clinical laboratory usage conditions including Sample/reagent preparation, centrifugation, storage.
Intended use:
Equipment used as a controlled temperature environment for incubating clinical laboratory tests.
Used for multiple techniques to accurately dispense required volumes of liquid
12-channel, adjustable pipetting volumes 5-50ul
Compatible with universal fit pipette tips ranging 5-50ul
Autoclavable, and Resistant to UV sterilization
A handle with digital setting and read-out of delivered volumes
Manual air displacement micropipette
Built-in tips ejector
Sturdy and chemical resistant parts.
Blood collection for clinical laboratory tests.
Capped, with a needle-pierceable vacuum seal.
Blood collection vacuum tube.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Applicable for automated analyzers.
Pen/Marker writable label space.
Blood draw volume 4.0ml.
Additive EDTA anticoagulant.
Standard color-coded cap.
Set of winter clothing for child aged 12 years.
....Cold box, Long term vaccine storage.
Storage capacity: 5.4L
Operating Ambient Temperature: +43°C
Vaccine storage Temperature: +2°C to + 8°C
Cold life at +43°C: 35 Days.
Vaccine storage capacity: 98.5 L
Volume category: >/= 60, <120L
Refrigerant: R600a, 45 grams
Energy consumption, stable running (kWh/24 hours): 1.23
Equipment operating voltage and frequency: 220-240 Volt, or 100-127 Volt and frequency 50Hz or 60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A.
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 135 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Remote Temperature Monitoring (RTM) system for real time monitoring of storage conditions at different levels of the vaccine cold chain: (a) with data access, setup of alarm thresholds and setup of alarm recipients through internet accessible dashboard (b) with automatic transmission of data to a server (c) with integrated audio-visual alarm (d) capable of alarm notifications via SMS, email and/or iOS & Android mobile applications (e) configurable to suit specific applications and scalable to allow for the later installation of additional temperature monitoring products and/or storage facilities.
....Capacity: 828L
Cabinet Type: Upright
Volume Category: ≥ 600 <900L
Operating ambient temperature: +10 °C - +32°C (Temperate zone)
Storage temperature: up to-86°C
Adjustable cabinet temperature set point -40°C to -86°C
Power requirement: 220-240V/50Hz.
Finishing: trimming to A4 size and packing 4 x 25 colors of each in a resealable plastic bag.
Paper: 180 GSM Bristol paper, 4 assorted pastel colors, pack of 100 sheets.
Size: A4
Arabic Student Kit for Grades 5 to 8.
....Armband, cloth.
Material - 220 gsm 100% washed cotton twill.
The material is color-fast, durable and easy to wash.
Adjustable Velcro closure consisting of two horizontal Velcro strips;
length 120mm x width 30mm; sewn along the outer side of the armband.
A third vertical Velcro strip sewn on the underside of the armband,
height 80mm x width 30mm
Color: 100% Cyan Blue
The colour is durable and does not bleach easily in strong sunlight.
There is no leaching of colour when the armband comes into contact with water.
Size: length 420mm x height 80mm.
Volley-ball net, official size 9.5 x 1m with minimum 100mm nylon mesh, thread size minimum 2mm; nylon headband, sides and bottom finished with heavy over lock stitch, 3mm steel cable; without standards or posts.
....