Mains Powered Vaccine Refrigerator 61 L

Product Code: LBNY-0004-2100013 - (Mains Powered Vaccine Refrigerator 61 L)

Vaccine storage capacity: 61L
Volume category: >/= 60, < 120L
Refrigerant: R600a, 60 grams
Equipment operating voltage and frequency.
220-240 Volt and frequency 50Hz/60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2?C to+8?C.

....


   

Solar Direct Drive Vaccine Refrigerator with no battery 59 L

Product Code: LBNY-0005-2100013 - (Solar Direct Drive Vaccine Refrigerator with no battery 59 L)

Vaccine storage capacity:59L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 45 grams
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.

....


   

30-Day Temperature Recorder, Int. Sensor, Refr

Product Code: LBNY-0006-2100013 - (30-Day Temperature Recorder, Int. Sensor, Refr)

The 30-Day Temperature Recorder (30DTR) can be connected to a PC via an USB interface cradle (LTI-HID) and generates a 32-day report via the free Analyzer 3 software, including all relevant information per day such as min/max and average temperatures, time out of range, alarm history etc. Data can be exported from the software in CSV file format.
The device shows the actual temperature, all alarm violations over the previous 30 days (on a rolling basis), the daily minimum and maximum temperature of the last 30 days, and the time duration of any violation. With internal sensor, is an electronic 30-Day Temperature Recorder (30DTR) with factory-programmed alarms and visual display for monitoring storage conditions in vaccine refrigerators (+2°C to +8°C) over a 30-day period.

....


   

Stirred Refrigerated Tank

Product Code: LBNY-0005-10700014 - (Stirred Refrigerated Tank)

Inner tank and outer casing made of stainless steel
Inner trap for emptying
Stainless steel measuring stick for the measuring of the milk level
DN50 threaded outlet connector with plug
Total primary surface evaporator with maximum yield
Non polluting polyurethane foam

Cooling System:
Compact design with space saving installation
Non icing cooling even with low filling level
R404A refrigerating fluid for all models
Direct expansion.

....


   

Trainer On Domestic Refrigerators With Two Evaporators And Hermetic Compressor

Product Code: LBNY-0005-11700014 - (Trainer On Domestic Refrigerators With Two Evaporators And Hermetic Compressor)

The Trainer On Domestic Refrigerators With Two Evaporators And Hermetic Compressor allows to study the circuit layout adopted in the normal domestic refrigerators with freezing room, fitted with positive temperature evaporator, negative temperature evaporator and hermetic compressor. A wheeled frame carries a horizontal working panel, fitted with a 80 mm clamp, and a vertical frame, where the main components of the unit and a screen printed synoptic panel are mounted at sight. The refrigerant is (HFC), CFC free, and the unit includes the measuring instruments that are necessary to monitor operating parameters and to test the refrigerator circuit. The student can rise his knowledge about the main components of a refrigerator plant, experiment the problems due to the filling and the emptying of the circuit and, at last, simulate some simple faults. The refrigerator circuit is made of copper pipes. The set of equipment and the vacuum and recharge station allow a fast assembly and disassembly of the refrigerator circuit.

Experiments:
Filling of a refrigerator circuit and leak detection.
Study of the main components.
Fault simulation.
Assembly and disassembly of the circuit.

....


   

Mains Powered Vaccine Refrigerator 211 L

Product Code: LBNY-0004-2100014 - (Mains Powered Vaccine Refrigerator 211 L)

Vaccine storage capacity: 211L
Volume category: >/= 120L
Refrigerant: R600a, 80 grams
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Equipment operating voltage and frequency: 220-240 Volt and frequency 50Hz / 60Hz, 1ph.

....


   

Solar Direct Drive Vaccine Refrigerator with no battery 46.5 L

Product Code: LBNY-0005-2100014 - (Solar Direct Drive Vaccine Refrigerator with no battery 46.5 L)

Vaccine storage capacity: 46.5 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 38 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.

....


   

Set Of Sectioned Components For Refrigeration And Conditioning Plants

Product Code: LBNY-0005-11700015 - (Set Of Sectioned Components For Refrigeration And Conditioning Plants)

The Set Of Sectioned Components For Refrigeration And Conditioning Plants set includes some of the most important components, used in refrigeration and conditioning plants such ascompressors, condensers, expansion valves etc. Special explanatory technical plates show each sectioned component explaining its operation with notes, drawings andtechnical data. In sectionizing each component the best care has been taken to evidence all the interesting constructive detailed features.The use of contrasting colors according to a pre-established code simplifies the informative process as well as the learningone.

....


   

Mains Powered Combined Vaccine Refrigerator and Water pack Freezer 30L

Product Code: LBNY-0004-2100015 - (Mains Powered Combined Vaccine Refrigerator and Water pack Freezer 30L)

Volume category: Vaccine storage capacity: 30L
Refrigerant: R600a, (45 +40) grams
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
PQS Prequalified Intermittent Mains Powered Combined Refrigerator and Water-Pack Freezer for storage of vaccines at +2 ?C to+8?C and freezing of water packs.
220-240 Volt or 50Hz / 60Hz, 1ph

....


   

Solar Direct Drive Vaccine Refrigerator with no battery 99 L

Product Code: LBNY-0005-2100015 - (Solar Direct Drive Vaccine Refrigerator with no battery 99 L)

Vaccine storage capacity: 99 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 76 grams

....


   

Refrigeration And Air Conditioning Unit And Two Evaporators

Product Code: LBNY-0005-11200016 - (Refrigeration And Air Conditioning Unit And Two Evaporators)

Bench-top unit.
Diagram in the front panel with similar distribution to the elements in the real unit.
Cooling compressor, computer controlled.
Anodized aluminium structure and panels in painted steel (epoxy paint). Main metallic elements in stainless steel.
Air evaporator, computer controlled. Water evaporator.
High pressure control.
Coolant accumulation tank. Cooling filter. Tank of division of the cooling liquid.
Expansion valve.
Water condenser.
2 Pressure sensors: Cooling pressure sensor (compressor outlet). Cooling pressure sensor (compressor inlet).
4 Manometers.
3 Flow sensors: Cooling flow sensor. Water flow sensor (water condenser). Water flow sensor (water evaporator).
Wattmeter.

....


   

Mains Powered Combined Vaccine Refrigerator and Water pack Freezer 58 L

Product Code: LBNY-0004-2100016 - (Mains Powered Combined Vaccine Refrigerator and Water pack Freezer 58 L)

Volume category: Vaccine storage capacity: 58 L
Energy consumption, stable running (kWh/24 hours): 1.91
Equipment operating voltage and frequency: 220-240 Volt 50Hz /60Hz, or 100-127 Volt 50Hz /60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF- Grade A
Refrigerant: R600a, 68 grams
Prequalified Intermittent Mains Powered Combined Refrigerator and Water-Pack Freezer for storage of vaccines at +2 ?C to+8?C and freezing of water packs.

....


   

Solar Direct Drive Combined Vaccine Refrigerator and Waterpacks Freezer with no battery 36 L

Product Code: LBNY-0005-2100016 - (Solar Direct Drive Combined Vaccine Refrigerator and Waterpacks Freezer with no battery 36 L)

Vaccine storage capacity: 36 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 40 grams, R600a, 30 grams, R290, 10 grams.

....


   

Heat Exchangers In The Refrigeration Unit

Product Code: LBNY-0005-11200017 - (Heat Exchangers In The Refrigeration Unit)

Heat exchangers are essential elements in refrigeration systems. A heat exchanger is an energy (heat) exchange system between a hot and a cold fluid. On the other hand, during heating, exchangers are used as refrigerant condensers to discharge energy. In some refrigeration cycles, depending on the application, it is necessary to superheat or supercool the refrigerant. In refrigeration circuits, during cooling heat exchangers are used as evaporator, to absorb energy from the refrigerant. 
Experimental unit for the training of apprentices for refrigeration area. The unit includes wheels for its mobility. Main metallic elements made of stainless steel. Diagram in the front panel with distribution of the elements similar to the real one. Anodized aluminum frame and panels made of stainless steel.

....


   

Mains Powered Vaccine Refrigerator 100 L

Product Code: LBNY-0004-2100017 - (Mains Powered Vaccine Refrigerator 100 L)

Vaccine storage capacity: 100L
Volume category: >/= 60, < 120L
PQS Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
Refrigerant: R600a, 80 grams
Equipment operating voltage and frequency: 220-240 Volt and frequency 50Hz / 60Hz, 1ph.

....


   

Solar Direct Drive Vaccine Refrigerator with no battery 220 L

Product Code: LBNY-0005-2100017 - (Solar Direct Drive Vaccine Refrigerator with no battery 220 L)

Vaccine storage capacity: 220 L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 65 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A

....


   

Refrigeration And Air Conditioning Unit One Condenser Air And Two Evaporators Water And Air

Product Code: LBNY-0005-11200018 - (Refrigeration And Air Conditioning Unit One Condenser Air And Two Evaporators Water And Air)

Bench-top unit. Anodized aluminium structure and panels in painted steel (epoxy paint). Main metallic elements in stainless steel. 
Air condenser, computer controlled.
High pressure control.
Coolant accumulation tank. Cooling filter. Tank of division of the cooling liquid.
Diagram in the front panel with similar distribution to the elements in the real unit.
Cooling compressor, computer controlled.
Expansion valve.
Air evaporator, computer controlled.
Water evaporator. 
4 Manometers.
2 Flow sensors: Cooling flow sensor. Water flow sensor (water evaporator).
9 Temperature sensors (4 sensors measure the cooling temperature, 2 sensors measure the water temperature, 3 sensors measure the air temperature
2 Pressure sensors: Cooling pressure sensor (compressor outlet). Cooling pressure sensor (compressor inlet).
Enthalpy diagram of the refrigerant R134a.
Wattmeter.

....


   

Mains Powered Vaccine Refrigerator 241 L

Product Code: LBNY-0004-2100018 - (Mains Powered Vaccine Refrigerator 241 L)

Vaccine storage capacity: 241 L
Volume category: >120L
Energy consumption, stable running (kWh/24 hours): 2.21
Operating temperature: Min and Max rated ambient temperature:?+10°C and +43°C
UIFPF- Grade A
Refrigerant: R290, 145 grams
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Equipment operating voltage and frequency: 220-240 Volt, 50Hz/60Hz or 100-127 Volt 50Hz/60Hz, 1ph.

....


   

Solar Direct Drive Vaccine Refrigerator with no battery 50 L

Product Code: LBNY-0005-2100018 - (Solar Direct Drive Vaccine Refrigerator with no battery 50 L)

Vaccine storage capacity: 50 L
Volume category: <60L
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 150 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.

....


   

Refrigeration And Air Conditioning Modular Unit

Product Code: LBNY-0005-11200019 - (Refrigeration And Air Conditioning Modular Unit)

Anodized aluminum structure and panels in painted steel.
Diagram in the front panel with similar distribution to the elements in the real unit
Main metallic elements in stainless steel.
Unit to perform experiments with a SCADA SOFTWARE.
System control via solenoid valves.
The unit includes wheels to facilitate its mobility.
Base unit of the unit that allows the development basic experiments on the operation of the refrigeration and air conditioning systems in conjunction with different models.
Function educational.
Models attached securely with fasteners.
Condenser unit with:  Compressor, Condenser, Receiver of refrigerant.
Data acquisition.
Automation of the air operation system.

....


   
< PREV    1 2 3 4 5 6 7 .. NEXT >
Support