N° 3 sets of deflectometers (without dial gauges)
....Solar Training Set (Sun Tracking)
....The Set Of Sectioned Components For Thermic Plants includes some of the most important components, used in thermic plants. Special explanatory technical plates show each sectioned component explaining its operation with notes, drawings and technical data. The use of contrasting colours according to a pre-established code simplifies the informative process as well as the learning one. In sectionizing each component the best care has been taken to evidence all the interesting constructive detailed features.
....Tuning Fork Set of 4pcs
....Potable Tool Set (Total: 56 pcs)
....Supplied in ready-to-use sealed vials
Save time and eliminate errors - no need for dilution
All concentrations are verified to meet tight quality control specifications, are EPA compliant for reporting purposes and are guaranteed to save time.
Turbidity Standards are stabilized Formazin standards prepared in ready-to-use concentrations to ensure accurate turbidity measurements.
This Power Supply Set includes an External Wall Mount with input plug set and a USB A to USB C cable. For use with turbidimeters.
For Use With (Equipment): Turbidimeter.
Type: Power Supply
Professional Trainer Set Electronic Engineering Lab
....A set of reusable, washable sanitary pads for menstrual protection to be used and reused for a duration of minimum one year.
Each set is comprised of:
2 Holders made of cotton
1 pouch for storage
3 Winged Pads
2 Straight pads
Pad material:
The holders have ribbon bands with edges well stitched by over-locking or other adequate fixation to secure the pads in position.
Pads are made of cotton, preferably flannel, for high absorbance on one side, and synthetic material on the flip side for protection against leakage.
Colors: grey or light brown.
GFS Chemicals Linear Calibration SetsHighly accurate, stable and reproducible standards for calibrating turbidimeters and nephelometers.
Designed for 90° white light turbidimeters.
Ready to use — no mixing or dilution required
Nontoxic and won't settle out of suspension
Guaranteed accuracy within 1%
Consist of polymer microspheres suspended in a pure, aqueous medium
Uniform in particle size distribution to ensure consistent light scattering and precise enough to permit calibration down to and including 0 NTU.
Indoor Solar Energy Training System Set Electronic Engineering Lab
....The Standard Set A, delivers all the concentrations needed to calibrate and verify the Portable Turbidimeter.
Save time and eliminate errors - no need for dilution
The standards are supplied in sealed vials, eliminating the need for preparation, and ensuring safe operation.
Turbidity Standards are stabilized Formazin standards prepared in ready-to-use concentrations to ensure accurate turbidity measurements.
Supplied in ready-to-use sealed vials
EPA approved as primary calibration standards
All concentrations are verified to meet tight quality control specifications, are EPA compliant for reporting purposes and are guaranteed to save time.
The Reusable Sensor is indicated for the continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (measured by an SpO2 sensor) for use with adult, pediatric, infant, and neonatal patients during both no motion and motion conditions and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments.
....Hand-operated in a vertical position; the inflatable bag is operated an upright position perpendicular to the body being ventilated.
The resuscitator is autoclavable between 121°C and 134°C.
The resuscitator has a provision which allows connection of oxygen tubing.
Portable, self-inflating, reusable.
The resuscitator is equipped with a non-rebreather valve.
Resuscitator is easy to disassemble, clean, disinfect, and reassemble.
The capacity of the self-inflating ventilation bag is between 220 ml.
The resuscitator is equipped with a pressure release (limiting) valve which safeguards against generating ventilation pressures over 45 cmH?O, while still allowing for an airway pressure of at least 30 cmH?O.
All parts manufactured from high-strength, long-life materials that require no special maintenance or storage conditions.
The resuscitator, all its components and accessories are free of natural rubber latex.
The pressure release valve should allow to be overridden by the user when higher pressures need to be generated in the airways.
When the pressure release valve is not overridden by the user, it should automatically return to its default position whereby it protects against excess pressures. Users should not be able to lock the pressure release valve in a permanent closed position whereby there is no longer a safeguard against excessive ventilation pressures.
Resuscitators are used for ventilation assistance in critical situations of respiratory distress or failure. It is considered essential equipment for health structures and emergency rescue team (to be available in emergency room, delivery room, operating theatre, intensive care unit, ambulance, etc.).
It is considered essential equipment for health structures and emergency rescue team (to be available in emergency room, delivery room, operating theatre, intensive care unit, ambulance, etc.). Resuscitators are used for ventilation assistance in critical situations of respiratory distress or failure. Resuscitator intended for full-term babies, preterm and low-weight infants up to 7 kg.
....It is considered essential equipment for health structures and emergency rescue team (to be available in emergency room, delivery room, operating theatre, intensive care unit, ambulance, etc.). Resuscitators are used for ventilation assistance in critical situations of respiratory distress or failure.
Hand-operated in a horizontal position.
Portable, self-inflating, reusable.
The resuscitator is equipped with a non-rebreather valve.
An oxygen reservoir bag should be included with a capacity between 600-2 ,600 ml.
Resuscitator can be fully disassembled, is easy to clean, disinfect, and reassemble.
The resuscitator is equipped with a pressure release (limiting) valve which safeguards against generating ventilation pressures over 45 cmH?O, while still allowing for an airway pressure of at least 30 cmH?O.
The resuscitator is autoclavable between 121°C and 134°C.
The capacity of the self-inflating ventilation bag is 500ml.
Ventilation can be done with ambient air or with oxygen.
The resuscitator has an inlet valve with a nipple for oxygen tubing.
All parts manufactured from high-strength, long-life materials that require no special maintenance or storage conditions.
The resuscitator, all its components and accessories are free of natural rubber latex.
The pressure release valve should allow to be overridden by the user when higher pressures need to be generated in the airways.
When the pressure release valve is not overridden by the user, it should either automatically return to its default position whereby it protects against excess pressures, or be clearly visible so there is no doubt as to its closed position, even during an emergencies. To ensure users are fully aware that the limiting valve is in closed position.
Aluminium cope and drag box, screwable
Pouring ladle with 5 kg Woods metal (melting point 70C)
Worksheets for instructor and students
Pattern plate with pattern of epoxy-resin in one piece
Core die, core iron
15 kg moulding sand in a separate container
Moulding tools
Thermometer.
Hand-operated in a horizontal position.
Portable, self-inflating, reusable.
Ventilation can be done with ambient air or with oxygen.
The resuscitator has an inlet valve with a nipple for oxygen tubing.
The resuscitator is equipped with a non-rebreather valve.
An oxygen reservoir bag should be included with a capacity between 2 ,500-2,600ml.
Resuscitator can be fully disassembled, is easy to clean, disinfect, and reassemble.
All parts manufactured from high-strength, long-life materials that require no special maintenance or storage conditions.
The resuscitator, all its components and accessories are free of natural rubber latex.
The resuscitator is autoclavable between 121°C and 134°C.
The capacity of the self-inflating ventilation bag is 1,600ml.
Precise, Pre-mixed Formazin Solutions. Based on Formazin Primary Standards. Enhanced Stability Saves Time and Labor. Confidence in results.
Stablcal calibration set with RFID, Laser Turbidimeter.