Workshop Multi process MMA, TAGS, MAGS
....Wireless Vacuum Gauge and P/T Gauge Combination
....This apparatus has asingle circuit with bends, pressure tappings and an expansion-contraction. Aball valve at the pipe exit controls water flow. The valve is downstream, so itdoes not cause any upstream turbulence. This compact bench-top apparatus uses smooth, industry standardplastic pipe, commonly used in domestic and other small-bore water systems. Itworks with Digital Hydraulic Bench. The bench supports the apparatus andcirculates and measures the water flowing through it. A useful diagram on the apparatus shows themain dimensions of the pipework and fittings. It also shows the positions ofthe tappings and the tubes that they connect to. Each pressure tapping point in the pipeconnects to a piezo meter tube in the vertical panel of the apparatus. The product includes ahand-pump to adjust the datum of the piezometer tubes. During experiments, these tubes measure and compare pressure differences across thebends, expansion and contraction.
....The system uses a high-pressure piston-recirculation pump to circulate product through the filter module of choice. The speed of the recirculation pump can be adjusted to suit the particular filtration module and the product. The triple-piston design combined with high-pressure flexibles minimises pressure pulsation. The operator can use their own feed vessel or this can be specified. Accidental system over-pressure is avoided by a bursting disc downstream of the recirculation pump. The retentate back-pressure valve enables pressures up to 50 bar to be achieved.
Features:
Variable retentate flow rate in order to change filtration cross-flow velocity
Retentate electronic flowmeter measurement
Retentate and permeate back pressure valves
Capable of microfiltration, ultrafiltration, nanofiltration and revese osmosis operations
Maximum filtration pressure of 50 bar
Clean-in-place capability
Backpulsing option (suitable for certain modules)
Mass balance option for permeate flow rate measurement
All parameters are data logged
Pressure sensors on the retentate inlet and outlet of the filtration module and on the permeate line.
The workstation is constructed of heavy-duty, welded steel. Industrial quality components are mounted and plumbed in a closed loop circuit to control the water flow between two tanks or the liquid level in one tank. The Level And Flow Process Control Learning System teaches two of the most common types of process control systems, flow and liquid level, and the basic concepts on which other systems are based. All components are connected to banana jacks on the control panel to allow students to measure signals and connect the devices in a wide variety of control configurations. Students will learn to calibrate, adjust, install, operate, and connect process control systems in industrial applications. The process control simulator includes a bench-top workstation, process control network, control panel, student learning materials for both theory and lab, and teachers guide.
This allows students to study a wide range of process control methods. The relay control includes manual input switches, control relays, solenoid valves, and float switches to perform automatic on/off liquid level control. Level And Flow Process Control Learning System offers 3 types of controllers: relay control, the standard, and two options: PID controller and PLC control. Manual valves are used to switch between the PID and on/off control methods. The PID controller option enables variable electronic control of either liquid level or flow and the PLC controller option enables both on/off and PID control of the system.
Features:
Interchangeable Components
Built-In Instrumentation
Industrial Standard Components
Student Reference Guide
Heavy Duty Welded Steel Workstation
Industrial Safety Devices
3 Types of Controller Options
PLC Interface
Multimedia Curriculum Available.
This kit consists of suitable accessories for determining emission rate, color and ph level, software program manual and light source. Its application can be noticed in various teaching laboratories, earth science center and chemistry labs. Transmissions Experiments Kit is used for suitable measurement of different attributes of transmission lines and their input impedance. This multipurpose training system is used for providing thorough knowledge on phase delay, standing waves, attenuation and frequency response. This kit is suitable for explaining theories associated with color measurement based transmission, atomic emission and so on. We are a prominent manufacturer and exporter of Transmissions Experiments Kit.
Features:
Easy to understand mechanism
Simple to use
Meticulously designed.
Reciprocating engines consist of a piston reciprocating in a cylinder and connected to a crank shaft by a connecting rod. This cover includes a switch, which allows automatically stops the drive motor if the cover is opened. The Computer Controlled Balance of Reciprocating Masses Unit is mounted on an anodized aluminum structure with panels of painted steel. It includes rubber elements to have a vibration isolation and a transparent protective cover protects students from the moving crankshaft and allows the visibility of the practical exercises and elements of the unit.
....The Heat Release apparatus measures time to ignition, mass loss and heat-release rate (option) of specimens exposed in the horizontal orientation to controlled levels of irradiance with an external igniter.
On the front panel, the following are mounted:
Load cell controller
Tare button
Temperature Controller
Control switches comprising four red on/off push-button switches, which operate by firm pressure and light up when activated:
Ignition switches on the spark-generator circuit housed in the test chamber base
Load cell switches on the Newport controller
Power switches on mains electricity to the unit
Cone switches on the Eurotherm controller. This, in turn, energises a solid state relay, which switches the power to the cone heater (5kW)
Features:
Special split shutter mechanism is designed to prevent heating of the sample before the test is started
Fire model manufactured from stainless steel for long life
Three control thermocouples for the cone heater to maintain accurate heat flux
Sample weight measurement is by a strain gauge load cell with quick electronic tare facility
Control unit contains switches for power, ignition, load cell and cone heater
Spark assembly is used in conjunction with the shutter mechanism. Microswitches are fitted to the spark arm and the shutter mechanism for safe operation
Load cell controller with a weight-ranging facility to improve performance to suit weight of sample 0-500g
Temperature controller for ramp and control of cone heater.
Domestically pioneered process-oriented design of testing control. Provides users with intuitive testing control procedures and a wide range of instruction types. Also supports dynamic instruction parameter assignment.
Constant loading speed test supported.
Capable of holding on maximum load or displacement.
Support for compression tests on various metal or non-metal materials to inspect their mechanics performances.
Dynamic display of load, displacement, time and real-time testing curve on the screen.
Domestically pioneered highly efficient three-level operation model of testing data processing. Supports open testing data processing, appending custom testing data items and re-inspection of processed testing data.
Closed loop control of channels such as load, displacement, etc. Smooth switching in between.
Domestically pioneered open-testing-method settings. Engineers may set up testing projects then operators may employ the projects for testing, greatly reduced the difficulty of the operations and the requirement in the skills and trainings of the operator.
Motorized draw-head assembly automatically compensates for specimen elongation and keeps loading bar with excellent load accuracy of +/- 0.5% guaranteed.
Both room temperature and elevated temperature systems are available
Furnace and chambers available with temperature ranges from 200C to 1100Cin common air environments
Control system owns the three closed control function as load control, extension control, and velocity control. High precise control and accurate load with load measurement resolution reach 1/300000; the loading testing curve can be plotted automatically.
This Series creep testing machine applies advanced servo motor and ball screw actuator which assure loading conveniently and simply. The drive system comprises a printed circuit motor with toothed belt and gearbox to the recirculating ball screw actuator.
Additionally, manual operation also be offered, users can unload to protect the apparatus by hand, especial the load cell, when suddenly power cut off.
Software owns powerful function offering specimens registration, apparatus control, test data acquisition and store, test result inquiring, data processing and test report export
Numerous high temperature pull rods, specimen holders, furnace systems and extensometers available for creep and stress Relaxation applications. Many of which are also adaptable to hot tensile testing applications on universal testing machines.
Remote communication control function saves your operators invigilation during testing process; alarm message can be transmitted to your mobile phone to inform you test situation by equipping with special dial number device.
Features a large test space that satisfies both GB requirements (longer than 60 times the specimens diameter), as well as American and European requirements (not less than 2.4 meters).
Real-time drawing of curves of remaining load with time, or temperature with time.
Support saving, instant retrieving and inspection of testing results.
Capable of re-analyzing test data and curves, and partial zooming of testing curves at will.
The measurement and control system is capable of backing up the transducers calibration data, improving the systems maintenance reliability.
Dynamic display of load, displacement, deformation and real-time testing curve on the screen.
Integrated with travel limit protection and full scale overload protection.
Open testing report, support custom testing template, automatic generation of testing report, which can be printed, previewed or saved as files.
Support Excel report templates and customized editing of test reports.
Algorithm to predict specimens stress relaxation performance after 1000 hours (or any specified value in hours), with the option of single or double logarithm. Capable of predicting with standard specimen data or real-time collected data (Suggested). Integrated with an extensive specimen library to improve the precision and reliability of testing results.
The engine can Be provided with a specific cylinder head fitted with Devices for the multi-channel indicator for Diagrams. Other cylinder heads for the gasoline engine Variable compression ratio are provided to allow To study the effects on the efficiency of the engine. Anything Instrumentation and controls are located on the Control panel made of melamine resin which comprises Multicolor synoptic table. The instrumentation provided is highly accurate, Includes an electric sensitive dynamometer, which allows To achieve fair and repeatable results.
....The Fluid Science Energy Losses in BendsSystems Tray provides hands on experimentation designed to demonstrate energylosses due to the geometry of the flow path at different flow rates.
Differential pressure reading is takenusing a digital manometer against varying flow rates.
Utilising the service unit theexperiments rapidly mount onto the multifunctional work panel and is connectedto the built-in water supply via quick connect couplings.
The tray includes the following Hydraulic Circuits:
Energy losses in Bends
Mitre Bend, 6mm diameter.
Shallow bend Radii 75mm, 6mm diameter
Tight Bend Radii 25mm, 6mm diameter.
Portable ultrasonic scanning systems are used in physician offices, radiology departments, cardiology departments, emergency departments, critical care units and by mobile imaging service providers. The main benefit of point of care ultrasounds units is that it allows physicians to quickly determine whether an abnormality is present so they can make appropriate patient management decisions. They can also have important applications in disaster triage and mass casualty incidents.
....Container, round.
Smooth surface.
Material: Austenitic stainless steel.
Austenitic stainless steel composition: 18 - 20% chromium, 8 - 10% nickel.
Reusable.
Capacity: approx. 4 litres.
Internal diameter: approx. 300 mm.
Height: approx. 100 mm.
Thickness: approx. 0.8 mm.
Newborn resuscitation and support of transition of infants at birth. Additionally, used to provide thermal support for newborns in the delivery suite and for critically ill infants who require constant nursing intervention. Mobile resuscitation table for neonatal patients equipped with a radiant warmer and supplied with accessories.
....Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
....Bench-Top Drill Press and Spindle Sander
....Passive Safety Devices For Motorcars simulator allows the study, the testing and the troubleshooting on the devices which have been developed for the purpose of increasing the safety of driver and passengers inside motorcars. The simulator considers all those systems that allow to reduce the consequences of accidents; in particular, the following devices are analyzed:
Air bag (driver bag, passenger bag, side bag, window bag)
Passive Safety Devices For Motorcars simulator allows the Multi-function valve in the fuel tank
It is possible to simulate the behaviour of components and circuits, on the basis of operating conditions that students and teachers can control directly on the panel or through the personal computer. The different not acting safety devices are reproduced on the panel through a synoptic diagram that allows a complete analysis of the components and, in case, of the relevant electrical/electronic control circuit. The latter keeps constantly under control the simulation, by visualizing its behaviour by means of signals and analog and digital meters; in this way the student, through suitable measurements and tests, can proceed to the fault finding activity.