Experiments:
Safety control using the high and low pressure switch and flow switch
Plant start-up and system monitoring using the incorporated protection and safety devices
Study and understanding of the operation of a chiller unit
On-off control of the cooled water temperature.
Detecting the system operating parameters:
Calculation of thermal balances for the refrigerant and water circuit
Plotting of the refrigerant cycle on a pressure-enthalpy diagram of the refrigerant gas
Manual Transaxle FWD Cutaway trainer presents a Front Wheel Drive Manual Transaxle that allows for demonstration of shifting and clutch operation.
Features:
Late-model Recycled Manual Transaxle
Handles to operate clutch and rotate gear shafts
Powder-coated frame mounted on casters
Operating clutch
Gear shift
Service Manual Available.
Manual Transaxle Rebuild trainer presents the rebuilding and service of Manual Transaxles.
Features:
Rotating Rebuild Stand with Component Storage and Drain Pan
Recycled Transmission or Transaxle with Clutch
Service Manual Available.
This trainer presents a Rear Wheel Manual Transmission that allows for demonstration of shifting and clutch operation.
Features:
Operating clutch
Gear shift
Powder-coated frame
Handles to operate clutch and rotate gear shafts
Service Manual Available
Late-model Recycled Manual Transmission.
Horizontal air duct with 450 mm x 450 mm window.
Axial fan with digital speed control 0 to 4 meters per second.
2x digital thermohygrometers with digital displays.
4x aluminium drying trays 400 mm x 300 mm.
Electrical heating element array 2,700 watts.
Distillation column height 600 mm with 7 sieve trays.
Electronic balance with range 0 to 10 Kgs and 0.1 g resolution.
Digital anemometer with digital display.
Digital chronometer.
Emergency stop button
Electrical control panel in main cabinet.
An easy-to-use accurate volumetric fuel gauge for use with engine test sets and engines. All connections are made using self-sealing couplings. The couplings ensure the fuel gauge can be connected and disconnected quickly and efficiently with minimum loss or spillage of fuel. The fuel gauge consists of a precision-calibrated two-bulb pipette and control valves. It mounts on the instrumentation frame of the test set and connects between the fuel tank and the engine under test. Students record the time taken to consume a set volume of fuel, from which they can accurately calculate the flow rate.Suitable for use with petrol or diesel. Fuel enters the pipette from the tank. The fuel supply from the tank is then cut off via a valve so that the engine draws fuel from the pipette only.
....Manure Spreader Cutaway model is carefully sectioned for training purposes, professionally painted with different colours to better differentiate the various parts.
....Measuring a vapour pressure curve for saturated vapour
Bourdon tube pressure gauge to indicate pressure
Digital temperature display
Boiler with insulating jacket
Temperature limiter and safety valve protect against overpressure in the system.
The measured value of the slope of the graph (dT/dP)SAT obtained from the practical results can be compared with corresponding values calculated from the data in steam tables the German Physicist and one of the founders of Thermodynamics was instrumental in deriving the relevant Clausius-Clapeyron relationship. Marcet Boiler has been developed for investigating the relationship between the pressure and temperature of saturated steam, in equilibrium with water, at all pressures between atmospheric and 17 bar (250 lb/in²).
Features:
Boiler Lagged To Permit Rapid Heating And Arranged For Bench Mounting
Electrically heated boiler fabricated from heavy duty steel section
Supplied complete with safety valve, pressure gauge and water cock
The Marcet Boiler includes a special-purpose glass window. It allows students to see the internal construction of the vessel, to see the boiling process and to check the water level. The electrically-heated boiler holds water. As the water temperature increases, so does the pressure in the boiler. The apparatus consists of a rigid frame containing an insulated pressure vessel and an instrumentation and control unit. The Marcet Boiler is a simple experiment to show the relationship between pressure and temperature for saturated steam for comparison with published results. The frame also has extra space for the optional interface. A digital display shows the values in both SI and traditional units. A transducer and a thermocouple measure the boiler pressure and temperature.
....Many parts have been chromium-plated and galvanized for a longer life. Marine Inboard Diesel Engine With Inverter Cutaway model is carefully sectioned for training purposes, professionally painted with different colours to better differentiate the various parts, lubricating circuits, fuel system, cross-sections, cooling system etc.
....Many parts have been chromium-plated and galvanized for a longer life. Marine Inboard Diesel Engine Without Inverter Cutaway model is carefully sectioned for training purposes, professionally painted with different colours to better differentiate the various parts, lubricating circuits, cross-sections, fuel system, cooling system etc.
....Intended use:
Marking microscope slides for purpose of identification.
It consists of body housing, a geared screw jack and motor drive mechanism suitable for operation on 230 V, 50Hz, Single Phase, A.C. supply.
Marshall Apparatus Consists Of:
50KN capacity
Robust construction
Safety cut-off switch
Rate of travel 50.8mm/min
Holds a box of ear loop masks, while keeping the contents secure with a key lock.
For stand mount version, choose from sleeve sign, or no sign.
Choose the amount of gloves the glove holder holds.
Choose your mounting method: Stand (steel stand included), Wall mount (screws and anchors included), Magnet Mount (powerful magnets included), or Tape Mount (powerful VHB tape included).
Available holders for 2, 3, or 4 glove capacity.
Includes a type 1 steam sterilizer indicator which is designed to indicate exposure to steam, but not designed to verify either the correct functioning of an autoclave or whether items have been properly sterilized. Used to close paper crepe packs for steam sterilization. Easy released pressure sensitive adhesive, easy to tear paper, easy to remove.
....Used to close paper crepe packs for steam sterilization. Easy released pressure sensitive adhesive, easy to tear paper, easy to remove.
Pressure sensitive adhesive
Paper-based adhesive tape
Leaves no residue
Does not damage the surface to which it is applied.
Plain (without sterilization indicators)
Maintains integrity and sticks to surface during steam sterilization cycle and drying temperatures.
Size: width 17-21mm x length 48-52m.
The Mass Oscillations And Hammer Study Unit is provided with a constant level container connected to the water supply by means of a pipe.
In the hydraulic systems the flow variations produce two phenomena: the mass oscillation and the water hammer which are related each other but have different characteristics.
For the water hammer test, the unit is provided with a quick closing valve with manual control in order to obtain an immediate flow interruption.
The oscillation test section is made of stainless steel 3 m long provided with the valves necessary for the flow control and with two pressure measurement devices, the electric signal of which is sent to a double trace memory oscilloscope which allows to examine, in all the phases, the phenomena of mass oscillation.
The Mass Oscillations And Hammer Study Unit is available in two different solutions:
Hydraulic supply from mains
Hydraulic supply from provided with additional tank.
Experiments:
Determination of the transient pressure curve of a water hammer by means of an oscilloscope
Demonstration of the losses in the reservoir and in the balance tank
Water hammer demonstration
Mass oscillation demonstration
Visualization of oscillation characteristics in the balance pipe.