A centrifugal pump is mounted integrally in the framework and is connected to the filter inlet via a throttle valve and pressure gauge.
A fully self-contained plate and frame type filter press constructed entirely in stainless steel.
Filter surface area is 0.22m² and solids holding capacity is 1.5 litres.
A back pressure valve is located at the filter outlet.
The filter pack is made up of four plates and four frames, which will accept a dressing of seven filter sheets 200mm x 200mm.
The filter pack and sheets are compressed manually using a hardened steel screw thread.
The Compression Ratio can be changed without stopping the engine and without altering the combustion chamber geometry by means of a specially designed tilting cylinder block arrangement both during gasoline running and during Diesel running. Computerized Variable Compression Ratio Multifuel Engine Test Bed allows to perform experiments concerning this kind of engines. The unit consists of single cylinder, four stroke, Variable Compression Ratio (VCR) engine connected to eddy current type dynamometer for loading. Setup is provided with necessary instruments for combustion pressure and crank-angle measurements. The test bed includes a stand-alone panel box consisting of air box, two fuel tanks for duel fuel test, manometer, and fuel Measuring unit, transmitters for air and fuel flow measurements, process indicator and engine indicator. Rota meters are provided for cooling water and calorimeter water flow measurement. These signals are interfaced to computer through engine indicator for pv diagrams. Provision is also made to interface airflow, fuel flow, temperatures and load measurement.
....The unit is similar to the being a bench top mounted unit, and with a mimic of the refrigeration circuit on the front panel. The circuits are arranged within the evaporators to allow for hot gas defrosting. Faults that can be simulated include blockage of pipes, filters, failure of expansion devices, thermostats etc. However the circuit is considerably more complicated including one chamber for chilling and one chamber for frozen produce.
Experimental Capability:
Commercial Refrigeration Trainer principle is similar to the but covers a range of refrigeration faults.
It also covers a range of refrigeration faults include fault on the compressor, fault on the oil separator, fault on the constant pressure regulator, fault initiated by blocked freezer evaporator or liquid line or by restricted freezer liquid line or by blocked drier or by blocked condenser air path or by compressor short cycling, faulty check valve, fault on freezer TEV, refrigerator TEV etc.
The refrigeration trainer can be used as an introduction to the basics of refrigeration circuits including safety & operating switches conveniently built into the electrical circuits with the student assessing the consequences, & building up a diagnosis capability.
Features of Commercial Refrigeration Trainer:
Expansion of refrigerant is possible through a number of different devices such as a regulating valves & capillary tubes of various lengths. Pressure is displayed at two points on the circuit
Faults are cleared by releasing the depressed switches & by opening the hand valves. Adjustment faults may be introduced by setting incorrect values on the Pressure stats on the front panel.
The refrigeration trainer provides additional refrigerant capability, with both chiller & freezer chamber. A defrosting heater is provided driven by hot refrigerant gas. Fault initiation is also included
The training system provides functioning refrigeration circuits utilizing commercial control & components. It provides realistic training in setting up, operating & fault finding in refrigeration systems. The system operates with one of the latest environmentally acceptable refrigerants
A mimic of the refrigerant circuit is provided on the front panel showing the circuit comprising of compressor, condenser & evaporator with an insulated chamber.
The refrigeration trainer is mounted on a wheeled stand due to its weight but at bench top height to provide students with experience in the safety, operation & faults of a refrigeration system
Faults can be initiated by switches set in the control & monitoring circuits
Faults that can be simulated include blockage of pipes filter, failure of expansion devices, thermostats etc Faults are selected by depressing switches & by use of the hand valves.
The following can be seen:
Synchronization
Duplex clutch
Mechatronics
Pressure reservoir
Differential
Gear wheels
Parking lock
Oil pump and electric motor
Oil cooler.
It uses built-in function generator, digital voltmeter, six high-precision digital frequency meter. and has the extended area to achieve open teaching. Comprehensive Electronic Training Kit is integrated experimental box with digital and analog electronic kit.
....Cube Mould standard reinforced band, 150 mm side.
....Grinding Wheel: CBN Wheel For HSS Drill Bit/SD Wheel for Carbide Drill Bit.
Standard equipment: Twelve collets, Nineteen collets.
Complex re-sharpener of end mill & drill, one machine with two function, easy to use, economical and practical, with no skill requirement to grind.
Theoretical topics of Logic Circuits
The algebraic description of the logic gates
The theorems of the Boolean Algebra
Binary system
Logic functions
The truth tables
Fundamental logic operators
NOT, AND and OR logic operators
Use of the AND and OR operators as control devices for the transfer of logic Classic form of a function
Graphic representation of the functions
AND OR NOT function
Techniques for the minimization of the logic functions through the application of the theorems signals
OR exclusive logic operator
Characteristic parameters of the logic gates
Definition and characteristics of a combinatory logic network
NAND and NOR logic operators
Use of the NAND and NOR operators as control devices for the transfer of logic signals
The TTL family
The CMOS family
The Karnaugh maps
Encoders, decoders, multiplexer and demultiplexer
Fault simulation
The BCD code.
Using Photovoltaics: Grid-Connected Or Stand-Alone
Operation With Photovoltaic Simulator Or Actual Photovoltaic Modules
Grid-Connected Or Stand-Alone Operation
Inverter With Mpp Tracker For Grid-Connected Operation
Solar Battery And Lamp For Stand-Alone Operation
Commercially available combiner box .
Trainer With Electrical Components From Practical Usage Of Photovoltaics
Inverter And Charge Controller For Stand-Alone Operation.
Pick And Place Feeding Station starts the process of assembling a working industrial directional control valve. The Pick And Place Feeding Station is a mobile workstation with slotted work surface that contains an operator station, powered feed module, finished parts storage module, parts set, a pneumatic distribution module as well as an electrical distribution module, pneumatic pick and place manipulator, an electro-pneumatic valve manifold, and a digital I/O interface module. The Pick And Place Feeding Station teaches interfacing, problem solving, programming, sequencing and operation for pneumatic robots, material feeding systems, powered parts feeders, vacuum grippers, hall-effect sensors, and magnetic sensors.
Optional Multimedia Curriculum:
This thorough, exceptionally detailed curriculum is built to begin with the basics of material feeding and handling systems and steadily advance to more complex concepts and skills. Unmatched multimedia utilizes text, audio, and stunning 3D animations that engage learners in both theoretical knowledge and hands-on skills. Through partnerships with key industry leaders and leading edge educators, developed the right balance of knowledge and applied skills needed to train learners to work in their chosen field.
Features:
Powered parts feeder
Pneumatic robot
Hall-effect sensor
Magnetic sensor
Photoelectric sensor
Vacuum gripper
Material feeding system.
Single-stage compressor, air-cooled, with fan flywheel, intake filter and pipe unions
Assembly exercise for engineering training
Compressor consisting of piston and cylinder, housing, driving gear, cylinder cover with valves
Complete, disassembled piston compressor with small parts set and 6 assembly jigs in a storage case.
The allows the demonstration of the relationship between these forces on front wheel drive, rear wheel drive, and four wheel drive.
This unit is mounted on an anodized aluminium and steel structure. A pin can be inserted in different positions to represent the centre of gravity of the car. A car model is supported on a beam load cell and has road wheels.
A load transfer between front and rear wheels takes place under conditions of braking or acceleration of a vehicle (a car for example).
The designed to demonstrate and study this load transfer.
This unit allows to carry out practices and experiments to study the relationship between the forces involved in car braking and acceleration.
The problem of load transfer occurs since the accelerating or braking force is not applied to the centre of gravity of the vehicle but to the point of contact of the wheels with the road.
Pulleys, weight and cords are used to apply different horizontal braking or acceleration and inertia forces to the car.
The apparatus is equally suitable for student experiments or demonstrations. Model consists of a three-hinged deck suspended by ties from a light cable. This bench-mounted apparatus is used to investigate the structure under a wide range of load conditions. Cable can be readily adjusted to give different values of dip over the 1m span.
....Electrical Program provides for the understanding of circuit reading and knowledge of wiring diagrams. Electrical Program is the basic Electricity Trainer used in training programs. Symbol graphics are screened onto each component with a white acrylic background. Using this Program students gain a foundation in the basic principles of electricity and electronics while getting a "hands on" working knowledge of voltage, current, and resistance through series and parallel circuits.
....Intended use:
Used in wide range of laboratory services from hospital laboratory to reference centre. Self-adhesive stickers for labelling samples or reagents to be frozen.
OXYGEN PRODUCTION
Provides a continuous, variable flow of concentrated oxygen 93% (±3%) derived from room air, to a maximum rate 8 L/min.
Audible and visual alarms for high temperature and pressure failure.
Power efficiency ≤ 70 W/LPM.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting.
Contains oxygen monitor to verify concentration.
Equipped with two oxygen outlets each provided with controllable flow meter.
Audible and/or visual alarms for low oxygen concentration (<82%) and power supply failure.
Flowmeter continuously adjustable, with markings of at most 0.5 LPM intervals.
Noise level <60 dB(A).
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.
ELECTRICAL CHARACTERISTICS
Mains power cable to have length ≥ 2.5 m.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical power requirements to be locally compatible.
230 Volt, 50 Hz, 2.1 amps (110 Volt units available)
Electrical protection by resettable circuit breakers or replaceable fuses.
CASING AND ENVIRONMENT
Case to be hard, to be cleanable with standard hospital cleaning materials.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Oxygen outlet to be securely mounted and sheltered.
Whole unit to be movable with four wheels.
The unit includes internally and externally mounted filters for cleaning the air intake.
Speculum, vaginal, self-retaining.
Double blade with a screw mechanism to keep the blades open.
To dilate the vagina to examine the vaginal canal and cervix.
Material: Austenitic steel (non-quenched, non-magnetic steel).
Austenitic steel composition: 16 - 18% chromium; 10 - 14% nickel; 2 - 3% molybdenum.
Blade length: approx. 95 mm.
Blade width: approx. 35 mm.
Reusable.
Endotracheal tube shall meet the standards concerning the dimension, the tube, the point, the cuff and the marking.
Endotracheal tube with:
Cuff located near the distal end: Low pressure cuff, inflating system with valve and Luer tip connector.
Open distal end and Magill-type point with oral angle of 37.5º.
Radio opaque mark.
With Murphy's Eye.
Graduations.
Standard connector (ext. Ø 15mm) at the proximal end enabling the tube to be connected to the ventilation system.
Material: Polyvinyl chloride (PVC).
Disposable.
Sterile.
Size: Ø internal 6.5mm.
Initial sterilisation method: Ethylene oxide gas or Gamma radiation.
The product is composed of a transparent wind proof cover, a hanging light aluminum foil ball, an angle indicator, a adjustable distance metal ball and a base. Transparent windshield size: 103mm*55mm*115mm, angle indicator range 0-70 degree, minimum angle: 1 degree, lightweight aluminum foil ball and a metal ball diameter: 20mm, the metal ball can adjust the distance of not less than 20mm. With a handle,the total size:165mm*90mm*135mm.
....It is used to make object vibration and sound production experiment, loudness and volume of sound experiment, object sound transmission experiment and simple telephone.
....