Structural Specifications:
Diagram in the front panel with similar distribution to the elements in the real unit.
Quick connections for adaptation to feed hydraulics source.
Stainless structure.
Screws, nuts, plates and all the metallic elements in stainless steel.
Gears transmit rotational movements. They adapt the torques and speeds of a consumer drive according to demand. Deals with a fixed gear unit. Worm gears are normally deployed to gear down, and are mostly self-locking. This enables components to be compared directly with the complete system. The gear unit comprises a worm gear with an upstream spur gear stage. Combining the two types of gear in a single box enables high transmission ratios to be attained at high levels of efficiency in a compact space. The comprehensive and clearly structured instructional material, which includes a set of drawings, sets out the individual assembly steps in detail and provides additional information on the areas of application, mode of operation and design of the assemblies. Large-format drawings suitable for workshop practice can be attached to the display board at the rear of the trolley. All steps can be demonstrated to, and then performed by, the students themselves.
....Anodized aluminum structure and panels of painted steel.
The unit includes wheels to facilitate its mobility.
Experimental unit for the training of apprentices for refrigeration area that allows the investigation of a refrigeration system with different expansion elements.
Diagram in the front panel with distribution of the elements similar to the real one.
Main metallic elements of stainless steel.
The Essentials of Process Control (EPC) range of products takes students through the fundamentals and principles of process control and progresses to give them a thorough grounding in the control of physical processes. Four independent process units demonstrate level, flow, temperature and pressure as the controlled variable.
The effect of making changes to the system or to the controller configuration can be quickly investigated by applying repeatable disturbances or step changes to the process. The concepts of closed loop control, including on/off control, proportional control, proportional/integral and proportional/integral/derivative (PID) control can be explored and demonstrated. Some units also cover both time proportioning and analogue control of the same parameter. Comparison of the responses obtained with different control settings clearly demonstrates the need for correct matching of the controller to the system characteristics. Each process is supplied complete with software that allows it to be controlled using a Windows PC via a USB connection.
The plc has the control algorithms implemented in ladder logic and so are fully accessible to the user. To demonstrate industrial control systems, two further controlling devices are available, a full function commercial PID controller with autotune, and a programmable logic controller (PLC). This is demonstrated by a sensor calibration apparatus designed specifically to demonstrate this subject. Another fundamental aspect of process control is an understanding of sensors and how they are calibrated.
Features:
Open Loop and Closed loop processes
Time proportioning control
Onset of instability
Manual loop tuning
On/off control (Fixed Dead Band)
P, PI and PID control
Underdamping and overdamping
Effect of Sample Time and Cycle Time
Sensor Calibration
Effect of filtering on sensor outputs
Commercial PID controllers
Ladder Logic controllers
Sensor electrical characteristics
Autotuning.
Handheld, portable, battery powered pulse oximeter, continuously displaying patient oxygen saturation (SpO2) and pulse rate in real time using an external probe on the skin.
Display:
Display with main parameters: SpO2, pulse rate, plethysmographic waveform, signal quality, alarm messages, battery state indication.
Data update period for valid data displayed ≤ 15s.
Features:
Audible and visual alarms for low/high saturation and pulse rate.
Audible and visual alarms for sensor error or disconnected, system errors, low battery.
Suitable for cleaning and disinfection with hospital-grade cleaning products.
Alarm override and temporary silencing function.
Capable of working with adult, paediatric and neonatal reusable probes.
Enclosure protection IPX1 or better.
Device and probe weight < 200 g.
Measurement:
SpO2 and pulse rate monitor, with plethysmography waveform, for adults, children and neonates.
SpO2 resolution 1 %.
SpO2 accuracy (in the range 70 - 100%) within ± 3%, for all patients and perfusion / movement conditions.
SpO2 detection includes the range 70 - 100 %. Also capable of measuring lower saturations.
Pulse Rate detection includes the range 30 - 240 bpm.
Pulse Rate accuracy within ± 2 bpm or ± 2%.
Pulse Rate resolution 1 bpm.
Pressure Sensors Calibration System
....The practice kit provides the material necessary for students to systematically learn how components can be joined together in a professional way using pins. Both flat and cylindrical parts are pinned together. We recommend that the exercises are carried out in a workshop, as all preparations such as scribing, drilling, clamping, reaming and joining must be carried out in a correct and proper manner by the student. The material is clearly laid out on a plastic tray. The well-structured instructional material outlines all the necessary technical information and provides a step-by-step guide through the exercises.
....The basic module includes the electrical equipment and the components for the Level control. The Modular Process Control Trainer system is a modular and low cost trainer based on Personal Computer and suitable to study the Process Control techniques. It is possible to carry out the laboratory activity in an extremely productive way using the potential of a Personal Computer. Some additional kits allow to fulfill the Flow, Pressure, Temperature, pH and conductibility control by using most of the basic module components.
....A Double-Compressor Air Conditioning Cycle Training Bench for studying the theoretical and practical aspects of the air conditioning cycle and the control of two compressors operating at different powers.
....For Use With (Equipment): Turbidity Meter
Replacement cuvettes
Type: Cuvette
Energy Losses in Bends
....Compressed air is often used instead of electrical energy, particularly in workplaces where there is a risk of explosion of combustible gases. The heat generated by compression is dissipated by cooling fins. Compressors are at the core of compressed air generator plants. These plants are used where compressed air is used as a source of energy. The compressor is driven by a V-belt. This enables references to be made between individual components and the Large-format drawings suitable for workshop practice can be attached to the display board at the rear of the trolley. A second fully functional compressor, permanently mounted to the workbench, can be used for demonstration purposes. A disassembled piston compressor is contained in the drawers of the trolley cabinet which also holds the tools and assembly aids, small parts and gaskets required for assembly.
....Horizontal air duct with 450 mm x 450 mm window.
Axial fan with digital speed control 0 to 4 meters per second.
2x digital thermohygrometers with digital displays.
4x aluminium drying trays 400 mm x 300 mm.
Electrical heating element array 2,700 watts.
Distillation column height 600 mm with 7 sieve trays.
Electronic balance with range 0 to 10 Kgs and 0.1 g resolution.
Digital anemometer with digital display.
Digital chronometer.
Emergency stop button
Electrical control panel in main cabinet.
The transmission can be turned easily, the gears changed byhand and compressed air applied in part. The shift lock is functional. Thetransmission is mounted on a table stand.
Cutaway are:
Dry clutch
Transmission case,
Oil pump,
Timing case
Pressure accumulator
Main shaft,
Clutch actuation.
Time of Flight Accessory
....Temperature programmable up to 2500C
Touch screen control panel
Variable speed fan
Built-in compressor
Heating system 3,000 watts
Atomization system with spray nozzle and cleaning device
Peristaltic pump adjustable up to 1,500 ml per hour
Exhaust pipe for solvent vapour
Cyclone with bottle for collecting the dried product
Drying chamber with collection vessel for residue
The lower value (diastole) corresponds to the pressure that we have in the arteries between two heart beats. The upper value (systole) is the maximum pressure that is recorded in the artery in consequence of the heartbeat. In blood vessels there must be a certain pressure in order that the blood can properly flow. Each heartbeat causes a pressure wave that is transferred to the arteries. Therefore, it is necessary to properly evaluate the pressure and its variability through a pressure and heart beat digital meter.
Circuit blocks of Blood Pressure Monitoring
Typical circuit used in Blood Pressure Monitoring
Measurement of the blood pressure and heart beat
Evaluation of the average cardiac rate
Theoretical topics of Blood Pressure Monitoring
Measuring the blood pressure
The sensors
The blood pressure
Hypertension.
Aeration of the trickling filter by natural convection or with compressor
Recording of concentration profiles is possible
Aerobic biofilm process for the degradation of organic substances and for nitrification
Secondary clarifier with pump for transporting the return sludge
All relevant flow rates finely adjustable
Transparent trickling filter with rotary distributor
Separate supply unit with waste water tank and two stirring machines
Two different carrier materials
Speed of the rotary distributor finely adjustable.
The kit can be assembled and disassembled as often as required and comes pre-filled with refrigerant.
An Industrial Air Conditioning Assembly Kit for teaching students to assemble and set-up an industrial air conditioner. Once assembled, temperature control can be studied.
The refrigerant used complies with anti-pollution legislation
Studying the operation of a water flow switch:
Analysing system behaviour and reactions with the variation of temperature set-point
Plotting the theoretical cycle on a refrigerant pressure-enthalpy diagram and calculating the thermostatic valve superheat
Studying the operation of a thermostatic expansion valve
ON/OFF control
System start-up